Questions

What the evidence can answer

Answers from published decoding results, each with its cohort, interval and limits.

Figures under one question often share participants: they are repeated conditions within its protocols.

Transfer

Does a decoder still work after a change of sensor, display, electrode layout, body movement or session?

Sensor transfer

Dry vs. wet electrodes

What changes when a decoder crosses between two native eight-channel recordings from the same 102 people?

2 s SSVEP · 12 targets · balanced accuracyRead the evidence →
Context transfer

Screen to VR

The same 21 people calibrated on a PC screen and tested in a VR headset, and the reverse: the level reached after the switch, with no same-display score to compare. Plus: a P300 decoder trained at one image rate and tested at another.

P300 · 21 people in VR · 9 people across image ratesRead the evidence →
Montage

Fewer electrodes

In-ear against scalp for sleep, four posterior electrodes against sixteen for eyes open or closed, foundation encoders on BETA with eight and four electrodes, and a simulated cap shift of one electrode spacing on BETA: channel sets from specific research recordings.

Two paired comparisons · 10 and 19 people · BETA, 8 and 4 electrodes, 70 people · a simulated cap shiftRead the evidence →
Motion robustness

On the move

Standing, walking and running results, with scalp and ear recordings and incompatible time windows kept apart.

SSVEP balanced accuracy · ERP ROC AUCRead the evidence →
Session transfer · same person

Later sessions

Trained on a person’s earlier session and tested on a later one, with no labels from it: motor imagery across recording sessions, with simple baselines and frozen CBraMod; target detection at the publisher’s nominal later visits; and continuous cursor tracking, where a constant baseline does better.

Motor imagery, WBCIC-SHU, 51 and 11 people · RSVP, 15 people · cursor tracking, a negative resultRead the evidence →

Adapting models

How much calibration a decoder needs, which part of a pretrained model to update, whether pretraining helps, whether one model can answer several questions, including questions asked in words, and what lets a decoder answer an SSVEP frequency it never trained on.

Calibration budget

How much calibration?

Twelve, 24 or 48 labeled trials on a wearable SSVEP task, and up to 40 from a person’s next motor-imagery session: the gain differs by method, and some people’s scores fall.

SSVEP · 102 people · motor imagery, next session · 51 peopleRead the evidence →
Model adaptation

Which part to update?

LaBraM on new people, same task, zero labels from the test person: head only, last block or LoRA, printed beside the core matrix’s frozen readout. Plus: the next-day experiment, run and held.

EEGMAT, 36 people · three update rules · next day: heldRead the evidence →
Representation controls

Does pretraining help?

Matched pretrained and constructor-random encoders under fixed and train-selected readout settings, and the same control for five further checkpoints on three tasks. Plus further foundation models in the same frozen recipe: three checkpoints and, narrowly, EEGPT above every published row on sleep staging, none above training-free CCA on BETA.

Three tasks · eight encoders · three random initializations · 23 further checkpointsRead the evidence →
Shared encoder · route 2

One model, several questions

One shared encoder with a fixed output per question, against a head told which question it is answering and against a separate model per question, at matched data and compute — with what each costs.

Motor imagery, OpenBMI, 51 people · sleep, BOAS · EESM19, crudeRead the evidence →
Questions in language · route 3

Questions in language

One small head over frozen EEG features, asked each question by a number, a label template or a description: it works only for questions it was trained on, and not on every dataset.

SSVEP, BETA, 70 people · sleep, BOAS · secondary: EESM19, OpenBMI, Wearable-102Read the evidence →
Route 3 follow-ups

New SSVEP frequencies

Fourteen follow-ups: thirteen on route 3’s BETA cohort, five on Wearable-102, one of them only there. Heads that read reference spectra or stimulus phase stayed far below CCA, which needs no training; a small learned correction on top of CCA added a few points on BETA and changed little on Wearable-102; filter-bank CCA, untrained too, scored above CCA in every setting tested, and an untrained harmonic sum came out nearly level with a learned eigenvalue head.

SSVEP, BETA, 70 people · 8 held-out frequencies · Wearable-102, 102 peopleRead the evidence →

Reliability & clinical

When a decoder should not act, what accuracy hides in sleep staging, what resting-state EEG says about a clinical group, and what a public dataset’s files show when checked end to end.

Abstention · decision research

When not to act

Command detection read with its false-activation rate; when a decoder should decline to decide, on two protocols; and the decision-research plan, with its three routes.

Idle, 4-person pilot · non-control, 20 people · reliable decisions, 36 and 70 peopleRead the evidence →
Sleep staging · simple baselines

Sleep-stage balance

Two simple baselines in 25 healthy sleepers and 55 people with sleep apnoea, as two separate experiments: accuracy beside balanced accuracy, and the stage the stager never predicts.

Dreem DOD-H and DOD-O · 25 and 55 nights · balanced accuracyRead the evidence →
Clinical research

Clinical groups

A 149-person Parkinson's and control comparison beside an age-and-sex-only comparator; neither is a diagnosis.

149 people · one site · balanced accuracyRead the evidence →
Data quality and reproducibility

Checked end to end

Public EEG datasets read from their own files: Shin2022’s runs, duplicates and valid windows counted before a participant-held-out check, where the EEG arm sits close to a control that reads only trial duration; training-free CCA on Kim beta-range SSVEP and on every eldBETA participant, with filter-bank CCA beside it there; MIND’s stored markers, read on record IDs; two one-person cases, Damm and NeBULA, with counts and no score; and a timing hold on one converted ZuCo run.

Shin2022, 10 people · Kim beta-range · MIND · eldBETA, 100 people · one-person cases, counts only · ZuCo, status onlyRead the evidence →
Decision researchJev-style questions on EEG: the evidence“Jev-style” here means the interface of a decision model like TypeSafe’s Jev, applied to EEG: encode the recording once, then answer several explicit, typed questions about it, each with a probability. Three routes, each answered by this site’s own runs on public EEG data.Read the evidence →

Transfer coverage

Which kinds of transfer have been measured

What changes between training and test, and whether this site has evidence on it.
What changesMeasuredStatus onlyHeldNot measured
PersonNew people: trained on others, tested on someone the model never sawNoneNone
Session / dayThe same person, another session or another dayNone
Sensor / montageAnother sensor type or another set of electrodesNoneNone
  • From one headset or amplifier to anotherEvery sensor change here is within one study’s own equipment.
ContextAnother display, movement, image rate, language or stimulus frequencyNoneNoneNone
DatasetTrained on one dataset, tested on another
  • BETA to Wearable-102, SSVEPn=102also changes: sensorModels trained on BETA, run unchanged on Wearable-102’s dry and wet headbands; the documentation cannot rule out that some people are in both.
NoneNoneNone

n is the number of people behind an entry; two sizes (n=24 / 17) are two analyses or cohorts in one entry, largest first. “comparison”: two electrode sets scored separately on the same data. “also changes”: what else changed in the same contrast.

Cohort sizes are read from the reviewed downloads: deployment-topics.json · adaptation-update.json · foundation-models-update.json · clinical-update.json · clinical-iesseeg-update.json · clinical-aseeg-update.json · large-source-update.json · beyond-scalp-update.json · data-quality-update.json · pilot-studies-update.json · neurolm-eegmat-update.json · neurorvq-update.json · later-sessions-update.json · context-update.json · evidence-update.json · electrode-shift-update.json · extension-update.json · new-ssvep-frequencies-update.json · Full holds register →