SSVEP
Steady-state visual evoked potentials track flickering visual targets at distinct frequencies over posterior scalp sites.
Start here
A five-minute field guide to scalp EEG tasks, fixed protocols, chance levels, and descriptive intervals — paired with six interactive checks drawn straight from published runs.
01 · Signals & scope
Tap any dotted term — such as EEG, SSVEP, or P300 / ERP — for an inline definition.
Electroencephalography (EEG) records tiny electrical voltage changes across sensors placed on the scalp. A brain–computer interface (BCI) turns those noisy waveforms into discrete selections or state estimates — such as choosing a flickering target on a screen, detecting a rare flash, distinguishing imagined hand movement from rest, or scoring sleep stages.
BCI Report runs classical signal-processing methods, compact neural networks, and frozen or adapted foundation encoders offline on public datasets under audited recipes. Every figure is aggregate cohort-level evidence: this site never performs live EEG inference, never publishes individual-person scores, and makes no clinical or diagnostic claim.
Steady-state visual evoked potentials track flickering visual targets at distinct frequencies over posterior scalp sites.
Event-related potentials are brief voltage deflections ~300 ms after a rare or attended visual or semantic target.
Imagining a limb movement without moving shifts mu and beta power over motor cortex, though patterns vary widely across people.
Scoring 30-second overnight windows into five sleep stages (Wake, N1, N2, N3, REM) where rare stages matter as much as common ones.
02 · Comparability
See how a participant-disjoint split and locked recipe keep method comparisons clean.
Two papers both labeled “motor imagery” or “sleep staging” are rarely interchangeable. Changing the dataset, electrode layout, window length, or split rule can swing accuracy by twenty percentage points even for the exact same code.
Every core benchmark table on BCI Report therefore locks four ingredients into a fixed protocol before any method runs:
Exact dataset version and participant count — from a 4-person idle pilot to 70 people on BETA SSVEP.
Fixed channel set and scalp layout (for instance, 8 vs. 4 posterior electrodes on BETA, or 6 scalp derivations on sleep).
All recordings from one person stay together on one side of a fold, testing transfer to unseen people rather than memorizing one person’s baseline.
Identical windowing, preprocessing, training budget, and metric across every method compared inside that column.
03 · Reading a number
Read balanced accuracy, chance level, and the descriptive 95% interval together.
A percentage on its own tells you very little. A 33.7% score on a 40-class SSVEP task sits more than 31 percentage points above its 2.5% chance line, whereas 51.0% on a 2-class P300 task sits right on its 50.0% chance line.
Beside every point estimate, BCI Report prints a descriptive 95% participant-bootstrap interval showing how much scores vary across the held-out people in that cohort. Compare the two real published slices below:
Key reading: Even the 33.7% row (CBraMod) stands more than 30 percentage points clear of uniform guessing across 40 targets.
Key reading: Spectral ridge prints 51.0% — a larger raw number than 33.7% above — yet its 95% interval (49.6–52.4%) crosses the 50% chance line.
| Protocol | Method | Balanced accuracy | Descriptive 95% interval | Chance level |
|---|---|---|---|---|
| SSVEP · 8 channels (40 classes) | CBraMod | 33.7% | 29.8–37.6% | 2.5% |
| SSVEP · 8 channels (40 classes) | EEGNet | 55.8% | 50.1–61.3% | 2.5% |
| SSVEP · 8 channels (40 classes) | Standard CCA | 63.1% | 57.2–69.0% | 2.5% |
| SSVEP · 8 channels (40 classes) | FBCCA | 79.1% | 75.1–82.8% | 2.5% |
| P300 target ERP (2 classes) | LaBraM | 49.4% | 47.7–51.2% | 50.0% |
| P300 target ERP (2 classes) | Spectral ridge | 51.0% | 49.6–52.4% | 50.0% |
| P300 target ERP (2 classes) | Temporal ridge | 53.8% | 51.9–55.6% | 50.0% |
| P300 target ERP (2 classes) | XDAWNCov+TS+LR | 61.9% | 58.8–65.0% | 50.0% |
04 · Interactive check
Before looking at the full matrices, test your intuition on six real findings from our published runs. Pick an answer to reveal the exact figures and protocol link — there is no timer and no score tally.
FBCCA 79.1% vs. Standard CCA 63.1% · paired mean +16.0 pp (98.75% interval +11.6 to +20.5 pp)
Weighting multiple harmonic sub-bands separates FBCCA from single-band CCA across the 70-person cohort, while neither method requires training data.
Inspect SSVEP · 8 channels protocol →Spectral ridge 72.2% (70.7–73.8%) · LaBraM 71.1% (69.0–73.2%) · ST-EEGFormer Large 79.6% (78.2%–81.0%) · EEGPT 75.5%
Foundation models do not act as a single monolith: some checkpoints overlap a fast spectral baseline while others separate above it under the same frozen ridge head.
Inspect sleep staging protocol →EEGNet 71.0% · 95% interval 65.0–76.3% (width 11.3 pp across 10 people)
On small cohorts, person-to-person spread spans over ten percentage points, so tiny differences in point estimates cannot be over-interpreted.
Inspect motor imagery & rest protocol →XDAWNCov+TS+LR 61.9% vs. Spectral ridge 51.0% · paired mean +11.0 pp (98.75% interval +6.8 to +15.1 pp)
P300 is a brief time-locked deflection rather than a steady spectral oscillation; Spectral ridge sits right on the 50% chance line while xDAWN extracts the evoked response.
Inspect P300 target ERP protocol →EEGNet: 1.7% command detection at 0.0% idle false activation · ShallowFBCSPNet: 43.3% detection at 1.7% false activation
A silent decoder never fires falsely, but never executes commands either — idle safety and command detection must always be read as a pair.
Inspect idle & command protocol →FBCCA 79.1% → 72.3% · EEGNet 55.8% → 44.1% · 4-ch paired difference +28.2 pp (98.75% interval +22.8 to +33.9 pp)
Cutting posterior electrodes in half lowers accuracy across methods, yet the training-free filter-bank structure still preserves strong frequency separation.
Inspect SSVEP · 4 channels protocol →05 · No single number
Different EEG paradigms obey different physics: frequency-locked visual responses (SSVEP), brief time-locked peaks (P300), slow spectral shifts (sleep staging), and idle false-activation trade-offs do not share one scale. Averaging them into a composite leaderboard number would erase which methods succeed on which signal.
Instead of collapsing protocols, inspect how methods cluster across tasks on the interactive 2D Method Map and Protocol Agreement view, or compare all frozen foundation encoders side by side across the eight core protocols.
06 · Next steps
Looking for a definition? Browse all 36 terms in the bilingual Glossary →