Five-stage sleep staging, healthy sleepers and people with obstructive sleep apnoea, kept apart
Dreem Open Datasets (DOD-H and DOD-O): EEG decoding results
The Dreem Open Datasets are two overnight polysomnography cohorts released to compare human and automated sleep staging: DOD-H, 25 healthy volunteers recorded at the French Armed Forces Biomedical Research Institute (IRBA), and DOD-O, 55 patients with obstructive sleep apnoea recorded at the Stanford Sleep Medicine Center. Both were scored by five sleep technologists from different sleep centres. Described by Guillot, Sauvet, During and Thorey in IEEE Transactions on Neural Systems and Rehabilitation Engineering (2020), with the official dreem-learning-open code; archived on Zenodo (record 15900394, published July 2025).
Also known asDreem Open Datasets · DOD-H · DOD-O · DOD · Zenodo 15900394 · Guillot et al. (2020)
Balanced accuracy, 2 configurations. Dot: the mean over nights; line: 95% interval. No dashed line: the training prior is a floor this baseline sets, not a chance level.
Method
Condition
Metric
Value
People
Training priorreference or comparator, not a decoding model
DOD-H · healthy sleepers, every night held out once
Balanced accuracy
20.2%20.0%–20.6%
25
Training priorreference or comparator, not a decoding model
DOD-H · healthy sleepers, every night held out once
Accuracy
48.0%44.6%–51.4%
25
Training priorreference or comparator, not a decoding model
DOD-H · healthy sleepers, every night held out once
Macro F1
13.0%12.3%–13.8%
25
Training priorreference or comparator, not a decoding model
DOD-H · healthy sleepers, every night held out once
Cohen’s kappa
0.0000.000–0.000
25
Spectral ridge
DOD-H · healthy sleepers, every night held out once
Balanced accuracy
56.7%53.1%–60.0%
25
Spectral ridge
DOD-H · healthy sleepers, every night held out once
Accuracy
72.3%67.8%–76.3%
25
Spectral ridge
DOD-H · healthy sleepers, every night held out once
Macro F1
53.3%49.0%–57.3%
25
Spectral ridge
DOD-H · healthy sleepers, every night held out once
Cohen’s kappa
0.5840.526–0.636
25
Spectral ridge
Spectral ridge minus training prior, the same nights
Paired difference, balanced accuracy
+36.5 pp+32.9 pp–+39.8 pp25 nights under both baselines; the interval excludes zero.
25
Spectral ridge
DOD-H · healthy sleepers · stage Wake
Recall
64.8%54.9%–73.9%3,037 Wake epochs in the consensus.
25
Spectral ridge
DOD-H · healthy sleepers · stage Wake
Precision
76.4%70.1%–82.3%
25
Spectral ridge
DOD-H · healthy sleepers · stage Wake
F1
66.5%58.5%–73.8%
25
Spectral ridge
DOD-H · healthy sleepers · stage N1
Recall
0.0%0.0%–0.0%1,505 N1 epochs in the consensus; never predicted on any night, so every one is missed and N1 precision is not defined (not zero).
25
Spectral ridge
DOD-H · healthy sleepers · stage N1
F1
0.0%0.0%–0.0%
25
Spectral ridge
DOD-H · healthy sleepers · stage N2
Recall
85.4%77.4%–91.8%11,879 N2 epochs in the consensus.
25
Spectral ridge
DOD-H · healthy sleepers · stage N2
Precision
77.3%72.8%–81.8%
25
Spectral ridge
DOD-H · healthy sleepers · stage N2
F1
78.9%74.0%–83.1%
25
Spectral ridge
DOD-H · healthy sleepers · stage N3
Recall
59.4%46.8%–71.2%3,514 N3 epochs in the consensus; defined on 24 of 25 nights.
25
Spectral ridge
DOD-H · healthy sleepers · stage N3
Precision
69.7%55.7%–81.9%defined on 24 of 25 nights.
25
Spectral ridge
DOD-H · healthy sleepers · stage N3
F1
56.2%43.6%–67.7%
25
Spectral ridge
DOD-H · healthy sleepers · stage REM
Recall
73.6%63.8%–82.6%4,727 REM epochs in the consensus.
25
Spectral ridge
DOD-H · healthy sleepers · stage REM
Precision
63.8%55.4%–71.5%
25
Spectral ridge
DOD-H · healthy sleepers · stage REM
F1
64.6%56.1%–72.2%
25
Sleep staging · DOD-O · people with obstructive sleep apnoea (a separate experiment)
Balanced accuracy, 2 configurations. Dot: the mean over nights; line: 95% interval. No dashed line: the training prior is a floor this baseline sets, not a chance level.
Method
Condition
Metric
Value
People
Training priorreference or comparator, not a decoding model
DOD-O · people with obstructive sleep apnoea, every night held out once
Balanced accuracy
20.5%20.1%–21.2%
55
Training priorreference or comparator, not a decoding model
DOD-O · people with obstructive sleep apnoea, every night held out once
Accuracy
49.2%46.3%–52.2%
55
Training priorreference or comparator, not a decoding model
DOD-O · people with obstructive sleep apnoea, every night held out once
Macro F1
13.3%12.8%–13.9%
55
Training priorreference or comparator, not a decoding model
DOD-O · people with obstructive sleep apnoea, every night held out once
Cohen’s kappa
0.0000.000–0.000
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea, every night held out once
Balanced accuracy
49.3%47.3%–51.2%
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea, every night held out once
Accuracy
72.5%69.7%–75.0%
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea, every night held out once
Macro F1
47.4%44.9%–49.7%
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea, every night held out once
Cohen’s kappa
0.5420.504–0.578
55
Spectral ridge
Spectral ridge minus training prior, the same nights
Paired difference, balanced accuracy
+28.8 pp+26.7 pp–+30.7 pp55 nights under both baselines; the interval excludes zero.
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage Wake
Recall
80.4%75.5%–85.1%10,427 Wake epochs in the consensus.
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage Wake
Precision
76.5%72.0%–80.7%
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage Wake
F1
75.6%71.7%–79.3%
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage N1
Recall
0.0%0.0%–0.0%2,860 N1 epochs in the consensus; never predicted on any night, so every one is missed and N1 precision is not defined (not zero).
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage N1
F1
0.0%0.0%–0.0%
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage N2
Recall
92.8%90.5%–94.7%26,271 N2 epochs in the consensus.
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage N2
Precision
71.0%67.9%–74.0%
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage N2
F1
79.8%77.3%–82.0%
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage N3
Recall
22.1%15.4%–29.2%5,500 N3 epochs in the consensus; defined on 52 of 55 nights.
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage N3
Precision
63.4%52.4%–73.9%defined on 49 of 55 nights.
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage N3
F1
27.9%20.3%–35.8%defined on 53 of 55 nights.
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage REM
Recall
49.5%43.1%–55.9%8,103 REM epochs in the consensus; defined on 53 of 55 nights.
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage REM
Precision
68.2%60.9%–74.9%defined on 54 of 55 nights.
55
Spectral ridge
DOD-O · people with obstructive sleep apnoea · stage REM
F1
52.5%46.0%–58.7%defined on 54 of 55 nights.
55
Source and licence
Dreem Open Datasets (DOD-H and DOD-O)
CreditAntoine Guillot, Fabien Sauvet, Emmanuel H. During and Valentin Thorey · Dreem Open Datasets: Multi-Scored Sleep Datasets to Compare Human and Automated Sleep Staging, IEEE Transactions on Neural Systems and Rehabilitation Engineering (2020), doi:10.1109/TNSRE.2020.3011181; preprint arXiv:1911.03221. Data: Dreem Open Datasets, Zenodo, doi:10.5281/zenodo.15900394. Official repository: github.com/Dreem-Organization/dreem-learning-open, revision 8b332d6827f5ae6a22f4bb97b4deef4273238ec3.
BCI Report does not redistribute any recording. These are aggregate measurements computed by BCI Report under the licence above; the data belong to the people credited.